Operat. pressure 120 bar (150 bar max)
Delivery rate max 660 l/h
Max steam Pressure / Temperature 10 bar / 178° C
Boiler absorbed power 3000 + 350 W / 230V ~ 50Hz (Ph 1)
Steam production dry/wet 50/90 kg/hh
Boiler type/ Volume Diesel / 2,83 l/h
Fuel tank capacity 18 l

#

Temperature regulator:
The temperature is set-up by an electronic regulator: it allows to obtain damp steam (low temperature) if our application needs a stronger kinetic energy; or saturated steam if the application needs a little water waste on the surface. A lower temperature produces a set lower working pressure accordingly to the steam physic law.

#

Discharge valve:
Allows a complete discharge of the boiler (not possible even through gun use). In this way it is possible to remove water and limestone residual inside the boiler and from the coil surface. This valve maybe opened only when the boiler is not hot, and it is recommended to accomplish regularly.

#

Unlimited autonomy:
The boiler is refilled by a water pump that gets water from an external water tank. This system allows an unlimited autonomy, because it is not necessary to turn off the steam generator and wait a lower temperature to refill with water. An automatic control recharges the boiler when necessary. In some models there is an acoustic signal advising about low water level inside the water tank.

#

Linear Pump:
The movement of the (3) pistons occurs through a system of connecting rods and crankshaft. The longitudinal axle of the pistons (placed at the same level or linear) is perpendicular to the motor rotation axle. It is more versatile to bear high delivery rates (from 21 l/ min) and it has a better self priming.

#

Motor low rotation speed:
The electric motor transfers the same number of revolutions to the pump. With a 4 poles motor there is a lower rotation speed of the components (1400 RPM in case of 50Hz or 1750 RPM in case of 60 Hz) granting longer pump life. Extending lifetime solution.


#

Flip through our UK catalogue
Download

#

Find your nearest LavorPro dealer:
Click here

#

Contact us about this product
Click here


#

Watch the video on our YouTube channel LavorPro YT Channel

UPDS Fuji

UPDS Fuji Image

Equipped with:

  • Steam: Vertical burner with high thermal efficiency steel coil. Auxiliary motor for burner.
  • Discharge valve: allows a complete discharge of the boiler.
  • Temperature regulator: temperature is set up by an electronic regulator. Steam pressure gauge. Temperature regulator. Low fuel lamp. Double pipe gasoil pump. User friendly control panel. Unit can be continually refilled. Safety solenoid valve. Device for cleaning hot water mixed with steam.

Technical characteristics

Operat. pressure 120 bar (150 bar max)
Delivery rate max 660 l/h
Max steam Pressure / Temperature 10 bar / 178° C
Boiler absorbed power 3000 + 350 W / 230V ~ 50Hz (Ph 1)
Steam production dry/wet 50/90 kg/hh
Boiler type/ Volume Diesel / 2,83 l/h
Fuel tank capacity 18 l

#

Temperature regulator:
The temperature is set-up by an electronic regulator: it allows to obtain damp steam (low temperature) if our application needs a stronger kinetic energy; or saturated steam if the application needs a little water waste on the surface. A lower temperature produces a set lower working pressure accordingly to the steam physic law.

#

Discharge valve:
Allows a complete discharge of the boiler (not possible even through gun use). In this way it is possible to remove water and limestone residual inside the boiler and from the coil surface. This valve maybe opened only when the boiler is not hot, and it is recommended to accomplish regularly.

#

Unlimited autonomy:
The boiler is refilled by a water pump that gets water from an external water tank. This system allows an unlimited autonomy, because it is not necessary to turn off the steam generator and wait a lower temperature to refill with water. An automatic control recharges the boiler when necessary. In some models there is an acoustic signal advising about low water level inside the water tank.

#

Linear Pump:
The movement of the (3) pistons occurs through a system of connecting rods and crankshaft. The longitudinal axle of the pistons (placed at the same level or linear) is perpendicular to the motor rotation axle. It is more versatile to bear high delivery rates (from 21 l/ min) and it has a better self priming.

#

Motor low rotation speed:
The electric motor transfers the same number of revolutions to the pump. With a 4 poles motor there is a lower rotation speed of the components (1400 RPM in case of 50Hz or 1750 RPM in case of 60 Hz) granting longer pump life. Extending lifetime solution.


#

Flip through our UK catalogue
Download

#

Find your nearest LavorPro dealer:
Click here

#

Contact us about this product
Click here


#

Watch the video on our YouTube channel LavorPro YT Channel

If You Need Any Commercial or Industrial Cleaning Solution... We Are Available For You

By continuing to use the site, you agree to the use of cookies. more information

The cookie settings on this website are set to "allow cookies" to give you the best browsing experience possible. If you continue to use this website without changing your cookie settings or you click "Accept" below then you are consenting to this.

Close